A beam pumping unit is not a steady load, and that load shape, not horsepower, is what selects the motor.

Quick answer

A pumpjack asks for torque twice per stroke: once when the sucker-rod string and fluid column are lifted, and once when the counterweight is lifted. NEMA Design D motors, defined at a rated slip of 5% or more, are the usual specification for it, and sizing follows the cyclic torque profile rather than nameplate horsepower.

Motor requirements

What a beam pump asks of a motor

ParameterWhat the application asks for
Load shapeTwo torque peaks per stroke: one lifting the rod string and fluid column, one lifting the counterweight. Torque requirements vary widely across the pumping cycle.
Rated slipNEMA Design D is defined at 5% or more. Designs A, B, BE, C and CE are all defined at less than 5% (ANSI/NEMA MG 1-2024, 1.19.1).
Locked-rotor torqueDesign D, 150 hp and smaller, 4-, 6- or 8-pole: not less than 275% of full-load torque (MG 1-2024, 12.38.3).
Derating on cyclic dutyAverage derating factor of 0.65 for NEMA Design C and 0.75 for NEMA Design D, because a cyclic load heats the motor more than the same average load applied steadily (SPE Petroleum Engineering Handbook, Vol. IV, 11.7.7).
Power factorAbout 0.87 at full load and about 0.76 at half load for a typical NEMA D machine; utilities commonly require better than 0.80 (SPE Petroleum Engineering Handbook, Vol. IV, 11.7.6).
Supply voltageNorth American sites commonly run 460 V or 575 V; IEC markets run 380 V or 660 V.

Why the load shape selects the motor

A motor meets a torque peak in one of two ways. It can hold speed and draw more current, or it can give up speed and draw less. Which one it does is set by its rated slip, and rated slip is what NEMA's motor designs differ on. A Design D rotor slows a little when the polished rod load arrives, so the peak is absorbed as a speed excursion rather than passed to the line as a current peak.

A stiff, low-slip motor answers each torque peak with a current peak. On a small distribution system that is objectionable, and it gets worse when several wells on the same feeder fall into step so their peaks coincide. The usual compensation is to fit a larger motor to get the breakaway torque. That leaves the motor oversized for the average load, running at a low load factor and a poor power factor, so the well pumps, the bill goes up and nothing on site looks broken.

Size on the cycle, not the nameplate

The most common sizing error on a beam pump is selecting on average power, finding the motor cannot hold strokes per minute under peak torque, and fitting something larger. Three steps, in this order:

  • Calculate the cyclic load. Well depth sets rod string weight and so peak torque. Conventional units typically run 4 to 12 strokes per minute. Peak torque capability and overload margin matter here; rated power alone does not say whether a motor can carry the top of the stroke.
  • Choose the drive topology. The conventional arrangement is an induction motor driving a gear reducer through belts. The alternative couples a permanent-magnet motor to the gearbox input shaft and removes the belt drive. Heavy oil and deep wells with high breakaway torque may be better served by a high-slip, high-starting-torque induction design, so not every well is a direct-drive candidate.
  • Verify the site. Confirm supply voltage and ingress protection, and specify higher protection for sites with heavy dust or salt exposure. A well that runs a progressive cavity pump rather than a beam pump is a different selection problem.

Belt-driven induction or direct-coupled permanent magnet

Induction with belt drivePM semi-direct drive
TransmissionBelt slip and wearNo belt stage
Wear partsBelts and motor bearings on a replacement cycleBelt and motor-bearing wear removed
Gearbox loadingSheave radial load carried by the gearbox bearingsImproved input shaft loading
Speed adjustmentChange sheaves, or add a VFDContinuously variable strokes per minute
Best fitBudget-led, standardised conventional wellsEnergy return, or wells with a history of gearbox failures

Energy saving from a direct-drive retrofit is measured against whatever was installed before, so a worn belt drive shows a large improvement and a well-maintained one a small one. Any specific figure should come from a survey of the actual well. Before converting, verify that the gearbox input shaft taper matches the motor standard.

What to send with an enquiry

Beam-pump sizing follows the cyclic torque and speed profile, not average kW alone. A recommendation made before the following is available is provisional:

  • Polished-rod load and stroke data
  • Gearbox output torque curve and counterbalance condition
  • Starts, reversals and duty cycle
  • Supply voltage and starting method
  • Regeneration and negative-torque portions of the cycle, which sizing from monthly energy use removes
Questions

Frequently asked

Why is NEMA Design D specified for oil well pumps?

Because of its rated slip. Design D is defined at 5% or more, while Designs A, B, BE, C and CE are all defined at less than 5%. High slip lets the rotor shed speed instead of current when a torque peak arrives, and Design D also develops high locked-rotor torque to break a loaded pumping unit away from standstill.

Can a standard Design B motor run a pumping unit?

It is done, and it has to be done carefully. A low-slip motor produces high cyclic current peaks, which is objectionable on a small distribution system, and getting enough breakaway torque from it usually means fitting a larger motor that then runs at a low load factor and a poor power factor.

Why derate a motor on a pumping cycle?

Because heating follows the RMS (thermal) current, which is always higher than the average input current an ordinary ammeter shows. The average derating factor is 0.65 for NEMA Design C and 0.75 for Design D, so a Design C machine gives up roughly a third of its nameplate on cyclic duty and a Design D a quarter.

Can a permanent-magnet motor replace an induction motor and belt drive on a beam pump?

Yes, driving the gearbox input shaft directly is what the design is for. Check that the gearbox input shaft taper matches the motor standard first, and confirm the well is a suitable candidate, since heavy oil and deep wells with high breakaway torque may suit a high-slip induction design better.

Going deeper

Engineering guides for this application

Why NEMA Design D is specified โ†’

The MG 1 clauses, the derating factors and the power factor threshold, with sources.

How to size a beam pump motor โ†’

The three-step method in full.

Pumpjack torque curves and motor sizing โ†’

The data to collect before a recommendation.

Pumpjack motor troubleshooting โ†’

From noise to nuisance trips.

Beam pump, PCP and ESP compared โ†’

How the lift method changes the motor.

Permanent magnet vs induction in oilfield duty โ†’

Where each one fits.

Where these figures come from: ANSI/NEMA MG 1-2024 clauses 1.19.1 and 12.38.3; SPE Petroleum Engineering Handbook, Vol. IV, 11.7.6 and 11.7.7; Lyons and Plisga, Standard Handbook of Petroleum and Natural Gas Engineering, 3rd ed..