AC Induction

YE3 (IE3)

YE3 (IE3) Series Three-Phase Induction Motor

The general-purpose workhorse: single-speed, totally enclosed fan-cooled, continuous duty, at IE3 efficiency across the full H80–H355 frame range.

IE30.55–375 kWIP55
YE series three-phase induction motor

YE3 meets grade 3 of GB 18613—2020 and IE3 of IEC 60034-30-1 — the level a North American buyer knows as NEMA Premium, although the two bodies publish their own tables and only the 50 Hz NEMA values are derived from IE3. It is a single-speed, totally enclosed, fan-cooled, continuous-duty low-voltage squirrel-cage induction motor for applications with no special requirement.

Frame numbering runs H80 to H355 with 2, 4, 6 and 8 pole variants, so the same series covers 3000 rpm fan and pump duty through to 750 rpm mill and conveyor duty without changing product line.

Core specifications

ParameterValue
Frame sizeH80 – H355 mm
Power range0.55 – 375 kW
Poles2 / 4 / 6 / 8
Voltage & frequency380 V, 50 Hz (custom on request)
Efficiency classIE3 · GB 18613—2020 grade 3
Protection degreeIP55
Thermal class155 (F), assessed to class B rise
CoolingIC411
MountingB3 / B5 / B35

Standards and certification

  • GB 18613—2020 grade 3
  • IEC 60034-30-1 IE3

Typical applications

  • Machine tools, fans, compressors, conveyors, mixers
  • Printing machinery, agricultural machinery, packaging machinery
  • General industrial drives with no hazardous-area or variable-speed requirement

Selection guide

Constant-speed duty running near rated load, where capital cost matters and there is no hazardous-area requirement. This is the default choice unless something specific pushes you off it.
The higher efficiency classes pay back through running hours, not through rating. The longer the annual operating hours and the higher the electricity tariff, the sooner YE4 or YE5 returns the price premium. The energy comparison calculator works that through for a specific rating.
If the duty is variable-speed, involves frequent starting, or spends much of its life at part load, an induction motor loses efficiency where a permanent magnet synchronous machine does not. See the TYC and TYP series.

FAQ

They are the same efficiency level, set by two different standards bodies — the NEMA standard derives its 50 Hz Premium Efficiency values from IE3 of IEC 60034-30-1 and says so in a footnote to that table. YE3 meets IE3 under IEC 60034-30-1 and grade 3 under GB 18613—2020. For the North American market LEADGO builds the NEMA PE series to the NEMA standard instead, because frame dimensions, voltages and frequency differ.
Datasheets, dimension drawings and certification copies are issued on request — tell us the rating and we will send the documents for that specific model.

Downloads

DatasheetPDF · 2.3 MBDownload
Installation & maintenance manualInstallation, commissioning and servicingRequest
CertificationCertificates and test reportsRequest

Certificates and test reports are issued against the specific model and rating rather than the series, so we send the ones that apply to your order. Tell us the rating and the market and we will send them.

Related products

Technical articles on this series

B3, B5, B35 and V1 Motor Mountings Explained

Practical engineering guidance on b3, b5, b35 and v1 motor mountings explained, including the checks, evidence and common mistakes that matter before purchas

Read

Belt Tension and Motor Bearing Life

Practical engineering guidance on belt tension and motor bearing life, including the checks, evidence and common mistakes that matter before purchase or comm

Read

Cooling Tower Fan Drives: Direct Drive or Gearbox, and What Decides It

The choice is about a drive train, not a motor. And whether the fan sits in the entering or the leaving airstream decides what the machine lives in.

Read

Reading a Chinese Motor Model Number: What Each Segment Commits To

YBX4-280S4-W is four segments in a fixed order, and the second character tells you the protection type before you find the Ex plate.

Read

How Dust, Oil and Moisture Damage Motor Windings

Practical engineering guidance on how dust, oil and moisture damage motor windings, including the checks, evidence and common mistakes that matter before pur

Read

Electric Motor RFQ Checklist: What Buyers Should Specify

Practical engineering guidance on electric motor rfq checklist: what buyers should specify, including the checks, evidence and common mistakes that matter be

Read

Replacing a Fan Motor: Why Matching the Nameplate Power Is Not Enough

Fan power rises with the cube of speed. A replacement motor running 2% faster asks for about 6% more shaft power, and nothing on the nameplate warns you.

Read

GB 18613, IEC IE and NEMA MG 1: How to Compare

A procurement method for reconciling Chinese efficiency grades, IEC IE classes and NEMA motor-efficiency requirements without false equivalence.

Read

Do High-Voltage Motors Have IE Classes? Only Inside a Narrow Window

High-voltage cage motors do get IE classes — between 200 and 2000 kW, above 1 kV to 11 kV, on two, four or six poles. Outside that, no class exists.

Read

How to Check If a Motor Nameplate's HP Is Inflated

A clamp meter and a published full-load current table are enough to catch an inflated horsepower rating. Here is the method, with worked numbers.

Read

How to Read an Electric Motor Performance Curve

Learn how to read motor current, efficiency, power factor, speed and torque curves before selecting or replacing an industrial motor.

Read

IE3 vs IE4 vs IE5: A Project-Lifecycle Selection Framework

A lifecycle framework for selecting IE3, IE4 or IE5 motors using operating hours, load, regulation, replacement constraints and measured losses.

Read

Insulation Resistance and Polarization Index

Practical engineering guidance on insulation resistance and polarization index, including the checks, evidence and common mistakes that matter before purchas

Read

What an Inverter-Duty Efficiency Figure Actually Measures

Converter-fed efficiency is tested against a standardised reference converter — good for comparing designs, not a prediction for your drive.

Read

Line-Start PM Motors: Permanent Magnet Efficiency Without a Drive

A rotor carrying both a cage and magnets starts like an induction motor and runs synchronously. The catch is what the magnets do during the start.

Read

Motor Bearing Selection: Ball, Roller and Insulated Types

Practical engineering guidance on motor bearing selection: ball, roller and insulated types, including the checks, evidence and common mistakes that matter b

Read

Motor Derating for Altitude and Ambient Temperature

Practical engineering guidance on motor derating for altitude and ambient temperature, including the checks, evidence and common mistakes that matter before

Read

Motor Efficiency at Partial Load: Beyond the Nameplate Value

Understand how industrial motor efficiency and power factor change at partial load, and when an oversized motor is worth replacing.

Read

Motor Frame Size vs Power Rating: What the Number Really Means

Why an IEC or NEMA motor frame identifies mechanical dimensions rather than one fixed power rating, and what buyers must verify before replacement.

Read

Motor Grease and Relubrication Intervals

Practical engineering guidance on motor grease and relubrication intervals, including the checks, evidence and common mistakes that matter before purchase or

Read

Motor IP Ratings: What Each Digit Is Actually Tested For

IP66 and IP67 are not two rungs of one ladder. One digit is about solids and people, the other about water — and above 6 the ladder stops working.

Read

Motor Manufacturing Tolerances: What Can Vary?

Practical engineering guidance on motor manufacturing tolerances: what can vary?, including the checks, evidence and common mistakes that matter before purch

Read

Motor Nameplate Photos to Request Before Replacement

Practical engineering guidance on motor nameplate photos to request before replacement, including the checks, evidence and common mistakes that matter before

Read

Motor Noise Limits: How to Specify and Verify Them

Practical engineering guidance on motor noise limits: how to specify and verify them, including the checks, evidence and common mistakes that matter before p

Read

Same Motor, Different Grid: 50 Hz and 60 Hz

Moving a motor between 50 and 60 Hz changes speed by 20%. What happens next depends on the voltage and on what the motor drives.

Read

Motor Phase Current Imbalance

Practical engineering guidance on motor phase current imbalance, including the checks, evidence and common mistakes that matter before purchase or commission

Read

Motor Shaft Dimensions and Coupling Fit

Practical engineering guidance on motor shaft dimensions and coupling fit, including the checks, evidence and common mistakes that matter before purchase or

Read

DOL, Star-Delta, Soft Starter or VFD: Which Start Method?

Compare DOL, star-delta, soft-starter and VFD motor starting by current, torque, control, mechanical stress and application fit.

Read

Motor Total Cost of Ownership: A Worksheet Buyers Can Audit

A practical motor TCO worksheet covering purchase, energy, installation, downtime, maintenance and end-of-life costs without relying on generic savings claims.

Read

Motor Trips After Two Hours: A Diagnostic Sequence

Practical engineering guidance on motor trips after two hours: a diagnostic sequence, including the checks, evidence and common mistakes that matter before p

Read

Voltage Unbalance: How a Small Supply Error Overheats a Motor

Learn how to calculate three-phase voltage unbalance, why it creates larger current imbalance, and what to check before a motor overheats.

Read

Why Motor Bearings Keep Failing After Replacement

Practical engineering guidance on why motor bearings keep failing after replacement, including the checks, evidence and common mistakes that matter before pu

Read

Rotor Balancing Grades: When Tighter Is Necessary

Practical engineering guidance on rotor balancing grades: when tighter is necessary, including the checks, evidence and common mistakes that matter before pu

Read

Soft Foot in Motor Installations: Checks Before Alignment

How to identify and document soft foot before motor alignment, with practical checks for shims, base distortion and bolt sequence.

Read

Where Synchronous Machines Are Used, and Why

Exact synchronous speed is the least interesting thing about these machines. What earns them a place is that you can choose the power factor.

Read

Reading Three-Phase Motor Terminal Markings: U1 V1 W1 and T1 T2 T3

Two marking systems, two rotation conventions, and one of them does not define rotation at all. Which one is on your terminal block changes what you can assume.

Read

Type Test vs Routine Test: What Each Report Proves

One proves the design, on a sample. The other proves this unit left the factory without a defect. Asking for "the test report" gets you whichever they have.

Read

VFD Reactors and Filters: Work Out Which Side the Problem Is On

Line reactors, dv/dt filters and insulated bearings are not stronger versions of one device. They fix three different problems in three different places.

Read

What TEFC Actually Means, and What It Does Not Tell You

TEFC describes an enclosure and a fan. It does not say how much dust or water the motor keeps out — that is the IP rating, specified separately.

Read

Why Buyers Don't Trust Chinese Motor Suppliers

Distrust of Chinese motor suppliers tracks four specific, checkable patterns, not the country of origin itself. Here is what each one is and how to verify it.

Read

Request a quote — YE3 (IE3)

Tell us the rating, quantity and application and an engineer will come back with a specification, the documents for that model, and a price.

Contact Sales